mercedes-benz Unimog Model Series 405 — UGE_Euro6_en.pdf

Data overview Hydraulic components Pump design Variable displace- ment pump Variable displace- ment pump Fixed displace- ment pump Fixed displace- ment pump Fixed displace- ment pump Variable displace- ment pump Variable displace- ment pump Drive Power take-off on engine i=1.0 Power take-off on engine i=1.0 Belt of engine i = 0.736 Belt of engine i = 0.736 Belt of engine i = 0.736 Propeller shaft on N05 i=0.935 Propeller shaft on N05 i=0.935 Hydraulic circuit Basic scope Based on fan hydraulics Circuit I Circuit I Circuit II Circuit III Circuit IV Filling capacity for oil reservoir Approx. 45 l Approx. 45 l Approx. 45 l Approx. 45 l Approx. 45 l Approx. 45 l Approx.

45 l Application Only vehicle internals Adjustment operations Adjustment ope- rations/oil supply Adjustment ope- rations/oil supply Oil supply Oil supply Oil supply Pump displacement cm3/rev 28 cm3 28 cm3 19 cm3 11 cm3 19 cm3 63 cm3 63 cm3 Pressure 200 bar 185 bar 210 bar 210 bar 240 bar 280 bar 280 bar Volume 62 l 62 l 62 l 62 l 62 l 50 l 50 l Qty. used 25 – 30 l 25 – 30 l 25 – 30 l 25 – 30 l 25 – 30 l 5 l 5 l Flow rate at engine speed 2200 rpm Approx. 20 l/min Approx. 20 l/min Approx. 55 l/min Approx. 32 l/min Approx.

55 l/min 90 l 90 l Maximum power [kw] 6,66 6,66 22 12,8 22 42 42 Fan hydraulics Tilting hydraulics Single circuit Dual circuit Work hydraulics Power hydraulics 51 Introduction of the New Unimog Generation | Model Series 405 – This printout will not be recorded by the update service. Status: 03 / 2013 –