ELECTRONIC CONTROL SYSTEM FUNCTION SELECTOR SWITCH X1 X1 ECT X3-10 AC DEMAND CAN1+ CAN 1(+) X2 X2 CAN1- CAN 1(-) X3-22 AC CONTROL X3 X4 X3 X4 CMP ECM HPSW LPSW T-STAT SW TO IGN SW h PDC APS 7 5 A/C CLUTCH RELAY 3 1 TO TRANS CONTROLLER 2 5 A/C CLUTCH BATTERY GRD TO BATTERY POSITIVE 200A MEGA FUSE F12 F34 A/C CLUTCH DIODE IGNITION SWITCH A/C Clutch Control • The VT 275 ECM controls the A/C clutch. The ECM receives an A/C demand signal from the chassis, and engages the A/C clutch if engine conditions are correct. If conditions are not right, clutch action may be delayed.
When the ECM receives the A/C demand signal, it considers engine run time (to avoid stalling at start up) and engine coolant temperature (to avoid compressor operation when liquid refrigerant may be present in the compressor). In addition, the ECM looks at transmission shift action (to avoid clutch action during a transmission shift), engine RPM (to avoid clutch overspeed), and APS percent (to avoid engagement during full throttle acceleration). on X3-10. The ECM supplies 5 volts to pin 10 and considers clutch engagement when the voltage is pulled low (shorted to ground) by the A/C on/off switch in the dash- located A/C Control Head.
A/C Control If the A/C demand signal is pulled low and the ECM determines that the clutch can be engaged, the ECM pulls the AC Control circuit low at pin X3-22. When pin 22 is low, a ground is provided for the A/C Clutch Relay. The relay latches and battery voltage is provided to the A/C clutch through pin 5 of the engine 12-way connector. The low-pressure switch (LPSW), high-pressure switch (HPSW), and the thermostat switch (T-STAT SW) are in series in the A/C demand circuit. If the compressor head pressure rises above 350 psi, the high-pressure switch opens and the demand signal will be 5V.
If pressure on the low side of the compressor goes below 7 psi, the low-pressure switch will open and the demand signal will be 5V. Switches The thermostatic switch (T-STAT SW) monitors evaporator core temperature to prevent freezing and to regulate cab temperatures. The low pressure switch (LPSW) prevents compressor damage in the event of a refrigerant leak. The last switch is the thermostat control in the A/C Control Head. If the thermostat is positioned so that in-cab temperature demands are satisfied, the thermostat will open and the demand signal will be 5V. The high pressure cutoff Switch (HPSW) interrupts compressor operation in the event of high system pressures.
A/C Demand The A/C demand signal originates at the ECM as a reference voltage 39 International ® VT 275 V6 Engine 1 2 C A