International Trucks VT 275 — VT275 manual

AIR MANAGEMENT SYSTEM Turbocharger Actuator The pneumatic actuator for the bypass valve receives intake manifold boost pressure from the intake elbow through a plastic tube. When the Pulse Width Modulated (PWM) signal to the boost control solenoid is 100%, the valve is open, and the boost pressure is vented to the inlet duct. With boost vented, the pneumatic actuator will be in the relaxed position. PNEUMATIC ACTUATOR PNEUMATIC ACTUATOR When conditions occur that would result in higher boost pressure than desired, the ECM reduces the PWM signal to 0%. The low signal causes the valve to close, boost builds in the actuator, and if boost is high enough, the actuator opens the diverter valve.

COMPRESSOR INLET COMPRESSOR INLET Actuator Line Routing • The ECM controls the venting of the actuator through the Boost Control Solenoid (BCS). Proper operation of the pneumatic actuator is dependent on the routing of the pneumatic lines. The actuator is connected through the black plastic tube to the rubber tee at the intake manifold elbow. The rubber tee at the intake manifold elbow is also connected to the BCS through a black plastic tube. The BCS is then connected to atmospheric pressure in the turbocharger inlet duct with a green plastic tube. When the BCS is open, the pressure in the black tube is vented to atmosphere through the green tube.

When the BCS is closed, pressure in the manifold will build in the actuator. AIR FILTER CHARGER AIR COOLER air MAINIFOLD AIR INLET ORIFICE BYPASS VALVE BCS exhaust out ACTUATOR MANIFOLD 45 International ® VT 275 V6 Engine