International Trucks VT 275 — VT275 manual

DIAGNOSTIC TESTS High Pressure Pump Test • The pump can be deadheaded by installing the ICP Leak Test Plug (ZTSE4690) in place of the rear left bank port plug, and the ICP Sensor Adapter ( also ZTSE4690) in place of the rear right bank port plug. Install the ICP sensor in the top of the ICP Sensor Adapter and connect the ICP sensor to the harness using the three-wire Pressure Sensor Breakout Harness (ZTSE4347) as an extension, if needed. Leave the valve covers off. Crank the engine while measuring ICP pressure. ICP SENSOR ICP SENSOR ADAPTER RIGHT BANK RAIL If the ICP pressure exceeds 500 psi, the pump is not at fault and there is a leak in the system.

• If the pressure is below the minimum cranking pressure, and there are no leaks around the pump, remove the pump from the crankcase. Oil should come up from the pump feed port in the crankcase indicating that the reservoir has oil. If the reservoir had oil, the pump is inoperative. ICP Diagnostics If there is lube oil pressure while cranking, the IPR functions, and there are no leaks in the hydraulic lines or rails, then either the pump is not getting oil from the reservoir, the pump is not turning with the crankshaft, or the pump is defective. Rotation can be verified by removing the high-pressure pump cover and cranking the engine while observing the pump gear.

Oil in the reservoir can be verified by removing the pump and observing the oil flow from the pump feed passage in the crankcase. Oil should come up from the pump passage indicating that the reservoir has oil. If the reservoir had oil, the pump is inoperative. 99 International ® VT 275 V6 Engine ICP Diagnostic Test Purpose KOEO Standard Test Verifies the IPR Circuit ICP System Function Test Verifies that the ECM can control the IPR IPR Function Test Verifies the IPR is working Under the Valve Cover Leak Test Locates leaks under the valve cover Cylinder Head Isolation Identifies which bank of cylinders has a high pressure leak High Pressure Pump Test Verifies the pump’s operation