DIAGNOSTIC TESTS Under Valve Cover Leak Test • If the IPR function test reveals a massive air leak, remove the valve covers and apply shop air pressure to the ICP System Test Adapter (ZTSE4594). Attempt to isolate the location of the leak. The possible leak points are: -Rail to injector O-rings -Rail fittings -Case-to-head tube and port plug O-rings -Branch tube assembly -Pump housing If the air leak is in the valve cover area, use a short length of rubber hose as a stethoscope to locate the air leak. If the air leak is from the crankcase (not the valve cover area), remove the case-to-head tubes and inspect the lower O-rings.
If the O-rings are good, remove the high- pressure pump cover and listen for the air leak at the pump-to-branch tube connections. Cylinder Head Isolation • If an air leak is heard, but the location cannot be detected, isolate each bank, one at a time, and test. To test the left bank, remove the left bank rear port plug and install the ICP Leak Test Plug (ZTSE4690) in place of the port plug. Leave the valve covers off, but connect the ICP sensor. Crank the engine while measuring ICP pressure. If the engine starts or ICP pressure exceeds 500 psi, the leak causing the low ICP is in the left bank.
ICP LEAK TEST PLUG To test the right bank, install the ICP Sensor Adapter (ZTSE4690) in place of the rear right bank port plug. Install the ICP sensor in the top of the adapter and connect the ICP sensor to the harness using the three-wire Pressure Sensor Breakout Harness (ZTSE4347) as an ex- tension, if needed. Leave the valve covers off. Crank the engine while measuring ICP pressure. If the engine starts or ICP pressure exceeds 500 psi, the leak causing the low ICP is in the right bank. LEFT BANK RAIL 98 International ® VT 275 V6 Engine