Fuel Injection Pumps, In-Line C Series Page 5-28 Section 5 - Fuel System - Group 05 Remove the fuel injection pump timing pin plug. Reverse the position of the timing pin. Install the timing pin, plug, and sealing washer. Tighten the timing pin plug. Torque Value: 15 N•m [ 133 in-lb ] CAUTION Failure to clean and dry the shaft and gear tapers thoroughly can result in timing shift to the retarded side after the engine is started and running under a load. This will result in low power, smoke, rough running, and engine damage. Tighten the fuel injection pump drive gear nut. Torque Value: Nippondenso Step 1 123 N•m [ 91 ft-lb ] Torque Value:
Bosch® P3000/P7100 Step 1 195 N•m [ 144 ft-lb ] Install the gear cover access cap hand-tight. Finishing Steps Install the governor oil supply line. Install the air fuel control air line. Install the fuel shutoff solenoid. Refer to Procedure 005-043. Install the control linkage. See the OEM service manual. Install the injector supply lines. Refer to Procedure 006-051. Install the fuel supply lines. Refer to Procedure 006-024. The MW-type fuel injection pump not equipped with engine-side fuel return option must be vented after installation. Loosen the vent screw located near the front on the side nearest the engine. Place the fuel control in the run position.
Crank the engine so that air can bleed from the fuel injection pump. Then, tighten the vent screw. Earlier MW-type fuel injection pumps were not equipped with a vent screw. Remove the large plug from the location described above to vent the fuel injection pump. A-type fuel injection pumps are self-venting. All P-type pumps were assembled with the engine-side vent option.