Fuel Injection Pump, In-Line, Spill Port Timing C Series Page 5-32 Section 5 - Fuel System - Group 05 The RSV governor throttle lever must be in the low-idle position and the shutdown lever needs to be wired or locked in the Ѕ-travel position. Turn on the spill timing cart pump. Check the fuel pressure. Fuel Spill Timing Cart - Fuel Pressure kPa psi 2068 MIN 300 2551 MAX 370 NOTE: The shutdown lever must be held in the required position before turning the spill cart pump on. Fuel must be flowing out of the tube attached to the fuel injection pump. If the fuel is not flowing, recheck the procedures carefully.
Slowly rotate the crankshaft clockwise , as viewed from the front of the engine, until fuel flow from cylinder No. 1 begins. The plunger No. 1 element is now approaching port closure. Continue to rotate the crankshaft slowly until the flow is reduced to a drip. At the point that the steady stream of flow changes from a solid flow to a drip, stop . This is the static timing position of the fuel injection pump.