Cummins — 3666003

Coolant Thermostat C Series Page 8-10 Section 8 - Cooling System - Group 08 Install a hose of the same size on the thermostat housing outlet that is long enough to reach a remote, dry container used to collect coolant. Install and tighten a hose clamp on the housing outlet. Torque Value: 6 N•m [ 50 in-lb ] Insert the end of the hose in a dry container. Operate the engine at rated speed for 1 minute. Shut off the engine and measure the amount of coolant collected in the container. Thermostat Leak Test - Allowable Leakage ml fl-oz 150 MAX 5 If more than 150 ml [5 fl-oz] of coolant is collected, the thermostats are leaking and must be replaced.

Complete the following in-chassis test to determine the thermostat opening temperature. Start the engine and monitor the water temperature gauge and the container. The thermostat initial opening temperature is: 81 to 83°C [178 to 182°F] Shut off the engine when the coolant starts to flow. NOTE: If coolant does not start flowing into the container during the initial opening temperature range, the thermostat must be replaced.