Cummins — 3666003

Cooling System C Series Page 8-18 Section 8 - Cooling System - Group 08 Cooling System (008-018) Coolant Replacer Method Evacuation The following steps are used to evacuate the cooling system using the coolant replacer tool, Part Number 2892459. NOTE: When the vehicle/equipment or engine is equipped with a quick disconnect fitting in the cooling system package, the Coolant Replacer Method is the preferred method for coolant removal. Use the coolant replacer tool, Part Number 2892459.

If the vehicle/ equipment or engine does not have a quick disconnect fitting presently installed, one can be installed in the cooling system package to utilize the Coolant Replacer Method; otherwise the coolant drain and fill method must be used. Position the equipment on level ground. WARNING Do not remove the pressure cap from a hot engine. Wait until the coolant temperature is below 50°C [120°F] before removing the pressure cap. Heated coolant spray or steam can cause personal injury. Do not use the coolant replacement tool to evacuate contaminated coolant or a system that is suspected of contamination. This could result in cross contamination of coolant.

The coolant drain method should be used for removing contaminated coolant. Refer to the manufacturer’s manual for specific instructions on cleaning the tool of contaminates. NOTE: Refer to the OEM service manual for special coolant drain requirements. Special instructions may also be located near the cooling system access point or fill door on the vehicle. CAUTION Isolate the engine from the vehicle cooling system by closing coolant flow valves to the equipment heating systems before starting the repair. This will prevent the heater circuit from draining, minimizing the chance for air pockets to be present during the fill process.

This air can be very difficult to purge in some applications with several feet of plumbing and multiple heater cores. Remove the radiator cap.