Cooling System C Series Page 8-30 Section 8 - Cooling System - Group 08 NOTE: The timing and sequence of this action will depend on the height of the petcocks in the cooling system. Fill the engine until a solid stream of coolant is visible from the keel cooler thermostat housing, heat transfer tube, and remote mounted heater petcocks. Close the petcocks. Fill until the coolant expansion tank is filled to the proper level and the low coolant level sensor is covered. Start the engine. Monitor the coolant level and the low coolant alarm until all air is purged from the system. Operate the engine for 5 minutes with the pressure cap removed, however, do not exceed 50°C [122°F].
Shut down the engine and check the coolant level again. Add coolant if needed. Install the pressure cap. Start the engine and monitor the low coolant alarm during the initial startup test. All Applications Except Marine CAUTION The system must be filled properly to prevent air locks. During filling, air must be purged from the engine coolant passages. Be sure to open the petcock on the aftercooler for aftercooled engines. Wait 2 to 3 minutes to allow the air to be vented; then add coolant mixture to bring the level to the top.
During all coolant fill procedures, all coolant flow valves to equipment heating systems must be opened in order to purge air from those systems as well as from the base engine cooling system. These valves must remain open during the engine cooling system de-aeration process. Make sure adequate coolant levels are maintained in the coolant reservoir during the entire fill procedure. Special care must be taken when filling EGR cooler-equipped engines to make sure all air is purged from the system. CAUTION The system is designed to use a specific quantity of coolant. If the coolant level is low, the engine will run hot.
If frequent addition of coolant is necessary, the engine or system has a leak. Find and repair the leak. The system has a designed fill rate of 19 liters [5 gal] per minute.