Sea Water Pump C Series Page 8-48 Section 8 - Cooling System - Group 08 Clean and Inspect for Reuse Inspect for damage such as rips, tears, chunks of material missing, or wear on the edges of the blades. Replace as necessary. Clean the internal pump surfaces. Lubricate the housing with silicone or glycerine non- petroleum-based lubricant. Petroleum-based lubricant will damage the rubber impeller. If non-petroleum-based lubricant is not readily available, use soapy water to ease installation. Install If the impeller is in good shape and will be reused, install it in the same direction from which it was removed. Refer to the mark you made during removal.
If the impeller was not marked and the original rotation or direction can not be determined, replace the impeller with a new one. An oil filter strap wrench or even plastic wire straps can be used as an installation aid to hold the vanes. Guide the impeller into the housing, twisting it counterclockwise as it is advanced so that the vanes will be deflected in the proper direction.