Intake Manifold Air Heater Element C Series Page 10-36 Section 10 - Air Intake System - Group 10 Intake Manifold Air Heater Element (010-124) Resistance Check Disconnect the ground cable from the battery. Remove all wires from the intake manifold air heater. Use an ohmmeter to check the resistance across both terminals. Use an ohmmeter to check the resistance from the ground of each positive heater terminal. The resistance should indicate zero ohms. If high ohms are indicated, inspect and clean or repair all heater electrical connections and grounds and recheck for zero ohms. A. Meter reads zero = good heater (both elements) B. Meter does not move = defective heater C.
Meter indicates, but not zero = dirty or corroded connections. Clean and repair, as necessary. Check the resistance from the ground wire to a known good ground. The reading should be less than 10 ohms. If not , replace the heater ground wire.