Cummins — 3666003

Intake Manifold Air Heater Control Module C Series Page 10-42 Section 10 - Air Intake System - Group 10 Post Heat Recycle If the intake manifold temperature, voltage, or engine rpm exceeds the test parameters prior to 20 minutes time cycle completion, the system will reset and a new 20 minute post heat recycle will be available. Perform these checks with the engine running under the same engine rpm, intake manifold temperature, and voltage condition as during the post cycle check. The post heat recycle will operate for 20 minutes, then shut off. Refer to the Intake Manifold Air Heater System General Information in Section F to verify the proper cycle.

Verify that the heater control module is functioning to the known temperature value being simulated for the intake manifold sensor. If the system is not operating at these known values, replace the heater control modules. Remove Disconnect the ground cable from the battery terminal. Remove the two mounting capscrews that hold the bracket to the engine block.