Cummins — 3666003

C Series Intake Manifold Air Heater Control Module Section 10 - Air Intake System - Group 10 Page 10-41 If no voltage is detected, disconnect the intake manifold air temperature sensor. Disconnecting the temperature sensor simulates intake manifold temperature of less than 0°C [32°F]. This overrides the temperature circuit if the intake manifold temperature is too hot to allow the heater to turn on. Turn the keyswitch OFF, then ON again. Recheck the voltage and ampere readings. Refer to Section E for the sensor location. Post heat cycle is dependent on temperature, voltage, and rpm. All must be in the specified normal operating range.

If the intake manifold temperature, voltage, or engine rpm exceed system parameters prior to the 20 second time cycle completion, the system will reset and a new 20 second heat cycle will begin. Refer to the Intake Manifold Air Heater System General Information in Section F to verify the proper cycle. If no voltage and no amperage are detected, check the following: Engine rpm is in the correct range Intake manifold air heater system voltage, refer to Procedure 010-122 Intake air heater solenoid switch, refer to Procedure 010-126 Intake manifold air heater element, refer to Procedure 010-124.

If all systems check out properly and the post heat does not cycle according to the heater cycle chart, replace the heater control module. System Voltage Voltage Range Amperage Range 12 10.5 to 17 80 to 110 (1 grid) 12 10.5 to 17 160 to 220 (2 grids) 24 22 to 29 80 to 110