Cummins — 3666003

Charging System Indicator C Series Page 13-14 Section 13 - Electrical Equipment - Group 13 Check the indicator lamp for normal operation as shown below: If the lamp is on when the switch is OFF and the engine is not running, disconnect the lamp lead at the ignition switch. If the lamp stays on, there is a short to a positive wire. If the lamp goes out, there is a short in the switch. If the lamp goes off when the switch is ON and the engine is not running, there can be an open in the circuit. Check for a blown fuse, a burned out bulb, defective bulb socket, or an open in the No. 1 or D (+) lead circuit between alternator and ignition switch.

If the lamp is on when the switch is ON and the engine is running, disconnect the lead to the alternator. If the lamp stays on, there is a short to the ground in the lamp circuit. If the lamp goes out, inspect the alternator. Engine Switch Lamp Ampmeter Stopped OFF OFF 0 Stopped ON ON - Running ON OFF +