Cummins — 3666003

C Series Crankcase Blowby, Measure Section 14 - Engine Testing - Group 14 Page 14-27 For ISB CM2150 engines that have the crankcase ventilation filter located at the rear of the engine, use the following steps to connect the blowby measurement tools. Disconnect the crankcase ventilation line from the crankcase ventilation filter housing. Plug or cap the crankcase ventilation filter housing. Connect the appropriate blowby service tool to the crankcase ventilation line exiting the flywheel housing. Connect a water manometer, pressure gauge, or transducer to the blowby service tool. For ISC and ISL CM2150 engines, use the following steps to connect the blowby measurement tools.

Remove the oil fill cap from the rocker lever cover. Install an oil fill adapter, Part Number 3990099. Connect the appropriate blowby service tool to the outlet of the oil fill adapter. Connect a water manometer, pressure gauge, or transducer to the blowby service tool.