C Series Crankcase Blowby, Measure Section 14 - Engine Testing - Group 14 Page 14-35 With the regulated shop air pressure line still connected to the air compressor governor/unloader air signal port, regulate the signal pressure so that the air compressor starts pumping (system pressure will begin to rise again at this point). Use the pressure value recorded previously as a set point. Operate the engine at rated speed and under load by either: For engine testing, a chassis dynamometer or engine dynamometer. A stall speed test (for engines equipped with automatic transmissions only ). Operate the engine at rated rpm and full load until a steady reading is obtained. NOTE:
When measuring blowby, the value can “spike” initially as the engine reaches peak power and rated speed. Wait for the blowby measurement to stabilize before taking a reading. Continue operating the engine at rated speed and load. Increase the signal pressure (system pressure stops rising at this point). Use the pressure value recorded previously as a set point. Operate the engine at rated rpm and full load until a steady reading is obtained. NOTE: When measuring blowby, the value can “spike” initially as the engine reaches peak power and rated speed. Wait for the blowby measurement to stabilize before taking a reading.