Flywheel Housing, REPTO C Series Page 16-24 Section 16 - Mounting Adaptations - Group 16 Disassemble NOTE: Use gear locking tool, Part Number 3823891, to prevent the output shaft from turning when removing the retainer capscrew. Remove the capscrew and washer that secures the output flange to the output shaft. Use a rawhide hammer to remove the output flange and flat washer from the output shaft. Use a dent puller to remove the seal. Do not damage the surface of the housing or seal bore. NOTE: When the housing is turned over, the bearing will fall out. Do not allow the bearing to be damaged. Turn the housing over so the four cover plate capscres are accessible.
Be careful not to damage the output shaft. Remove the capscrews and ribbed cover plate from the output gear housing. Remove and discard the square cut o-ring seal. NOTE: Save the original shims for rebuild purposes. They will be used to set the proper end clearance on the output shaft and bearing assembly. Turn the housing over and use a rawhide hammer to hit the end of the output shaft to remove the poutput shaft subassembly from the REPTO housing.