Air Intake System - Overview C Series Page F-32 Section F - Familiarization Intake heater grids Engine speed sensor Wiring. The intake heater system operates in three modes as follows: Preheat Cycle The heater control module receives and monitors supply voltage from the keyswitch. The heater control module receives electrical signals from sensors mounted on the engine. The temperature sensor senses intake air manifold temperature and provides input to the heater control module circuit. Temperatures below 35°C [95°F] activate the heater control module heater circuit. This is known as the preheat cycle. The heater control module provides signal voltage to active the air heater solenoids.
A cable connected to the battery side of the starter solenoid provides supply current/voltage to the air heater solenoid. Intake air temperatures sensed by the temperature sensor dictate different preheat cycle times, up to a maximum of 20 seconds. Both elements heat during this cycle. After the preheat cycle, the starter can be engaged to start the engine. If the starter is engaged before the cycle time is complete, the heater control module will automatically shut off the elements during cranking. Post Heat Cycle The engine speed sensor on the flywheel housing senses engine speed and activates the post heat cycle within a specified rpm range. The engine must be operating in a given range.
Battery voltage is monitored by the heater control module system. The temperature sensor continues to monitor intake air temperature. This cycle can continue for up to 20 seconds maximum and does not have a rpm cutout. Both elements heat during this cycle. The post heat recycle mode occurs for a maximum of 20 minutes; as long as the heater control module senses specified range of the air temperature, voltage, and rpm. Post Heat Recycle The post heat recycle activates the heater elements in two sequence modes: 25/75: Both elements alternately cycle on and off with a five-second delay between element activation. Each activation lasts for five seconds.
Only one element is activated at a time on a 12-VDC system. 50/50: Both elements cycle on and off for five seconds. Only one element is activated at a time. Post heat recycle operates for a maximum of 20 minutes. This operating cycle can be interrupted at any time, if any one of the following conditions occur: 1. Engine exceeds specified rpm, intake air temperature, or voltage range 2. Intake manifold temperature exceeds 35°C [95°F] 3. Heater control module battery sensing voltage below 10.5 VDC or above 17 VDC. If the post heat recycle is interrupted during its 20-minute cycle, the cycle will restart, and reset for another 20 minutes if all of the following conditions occur: 1.
Engine below 1000 rpm 2. Intake manifold temperature below 30°C [85°F] 3. Heater control module battery sensing voltage between 10.5 and 17 VDC. Once the 20 minutes of post heat recycle has ended, the ignition key must be turned to the OFF position and back to the RUN position to restart the air heater cycles again.