C Series Air Intake System - Overview Section F - Familiarization Page F-31 The proper operation of the intake manifold heater system and starting procedures will prevent excessive engine starter motor use and minimize white exhaust smoke when the engine is first started. WARNING Ether starting systems or manually-induced starting fluids must not be used with electric air heater systems. On C series marine applications, there are three phases of intake air heater operation: preheat (with keyswitch ON and engine not operating), post heat (after a successful engine start), and post heat recycle (after the termination of the post heat).
The preheat phase also controls the Optional WAIT TO START lamp to signify to the operator when it is appropriate to begin cranking the engine. In order to allow maximum current to be used by the starter, the heater elements are de- energized during cranking. The amount of time the heater stays in preheat, post heat, and post heat recycle is determined by the intake manifold temperature. There is no preheat cycle above 35°C [95°F], no post heat cycle above 24°C [75°F] and no post heat recycle above the maximum duration for preheat and post heat (20 seconds) and post heat recycle (20 minutes).
When the air intake temperature is below 35°C [95°F], the heating elements are energized in the preheat and post heat cycles, the voltage system current draw is approximately 200 amperes for a 12-VDC system and 100 amperes for a 24-VDC system. During the post heat recycle mode the heater elements are energized in five-second intervals for a maximum duration of 20 minutes. There are three optional conditions that will interrupt the post heat recycle mode: Out of voltage range, exceeding operational rpm, and air intake temperature above 35°C [95°F].
Once the grid heater post heat recycle mode terminates because of timing out or over/under keyswitch voltage, the grid heater will not come back on unless the keyswitch has been cycled from OFF to ON. If the engine rpm is advanced above the maximum set point (950 rpm for B series and 1200 rpm for C series engines), the post heat recycle will be terminated. Once the engine rpm is adjusted below maximum set point and air intake temperature is below 35°C [95°F], the post heat recycle will reset back to the beginning of the 20-minute cycle. The intake manifold heater option is installed between the aftercooler and intake manifold. The heater is totally electrically operated.
The intake manifold heater aids in reducing white smoke at startup and the engine's startability at colder temperatures. Components required to operate the intake heater are: Ignition keyswitch Heater control module Temperature sensor Solenoids Heater Cycle Chart Battery voltage above 10.5 to 17 for 12-VDC Rpm:
(B) 450 to 950, (C) 350 to 1200 Engine Intake Manifold Temperature Preheat Cycle Time Ignition Keyswitch ON before Crank Cycle Postheat Cycle Occurs Ignition Keyswitch ON after Crank Cycle Recycle Mode (After Post Heat) Above 35°C [95°F] None None None 24 to 35°C [75 to 95°F] 10 seconds None 25/75% (1) 15.6 to 23°C [60 to 75°F] 10 seconds 20 seconds 50/50% (2) 1 to 15.5°C [32 to 60°F] 15 seconds 20 seconds 50/50% (2) Below 0°C [32°F] 20 seconds 20 seconds 50/50% (2) Heater Operating Modes (Parameter) Recycle Mode 12-VDC Element (Heater) 5-Second Time Intervals (1) 25/75% 1 On Off Off Off On Off Off 2 Off Off On Off Off Off On (2) 50/50% 1 On Off On Off On Off On 2 Off On Off On Off On Off Recycle Mode 24-VDC Element (Heater) 5-Second Time Intervals (1) 25/75% 1 On Off Off Off On Off On (2) 50/50% 1 On Off On Off On Off On