I003578 Fig. 156. I003584 Fig. 157. Rotation angle of B055 sensor (A050 ECU, basic control unit) to great (more than 250 steps) Current from B055 sensor (A050 ECU, basic control unit) too high (above 21 mA) Current from B055 sensor (A050 ECU, basic control unit) too low (below 3 mA) F28 Error on saving the calibration to the EEPROM of the A050 base control unit 919 .. 0101-1000 925 .. 1001- 934 .. 0101-1000 919 .. 1001- 928 .. 0101-1000 934 .. 1001- 922 .. 0101-1000 928 .. 1001- 922 .. 1001- 931 .. 0101-1000 925 .. 0101-1000 931 .. 1001- Distance between idle and full throttle too short B055 sensor, foot throttle incorrectly calibrated F26 B055 sensor (A051 ECU, engine control unit):
Distance between idle and full throttle too short (less than 70%) or B055 sensor, foot throttle incorrectly calibrated F27 Time for a calibration increment exceeded (more than 60 seconds) O.K. appears 0000 - Overall system/tractor 282 T000393 Version 3 31-10-2008 F - Setting and calibrating Fault code Cause F21 Transmission not in neutral F22 Current from B055 sensor (A050 ECU, basic control unit) too low (below 3 mA) F23 Current from B055 sensor (A050 ECU, basic control unit) too high (above 21 mA) F24 Rotation angle of B055 sensor (A050 ECU, basic control unit) to great (more than 250 steps) F25 B055 sensor (A050 ECU, basic control unit):
Distance between idle and full throttle too short (less than 12 mA) or B055 sensor, foot throttle incorrectly calibrated F26 B055 sensor (A051 ECU, engine control unit): Distance between idle and full throttle too short (less than 70%) or B055 sensor, foot throttle incorrectly calibrated F27 Time for a calibration increment exceeded (more than 60 seconds) F28 Error on saving the calibration to the EEPROM of the A050 base control unit