Fendt 900 Vario COM III — 15 Calibration code 4007 (transmission ratio characteristic)

0000 - Overall system/tractor F - Setting and calibrating 287 T000399 Version 3 21-04-2009 Remedy: sary, e.g. via emergency operation. 2. Y005 speed governor solenoid valve A009 actuator unit reports a fault Frequent cause of fault: out F03 A009 actuator unit does not actuate the precise setpoint value. Check that the transmission control runs smoothly, e.g. engage and check emergency opera- tion. F04 Transmission ratio adjustment not effected within 8 sec. Check that the transmission control runs smoothly, e.g. engage and check emergency opera- tion. F07 Step 2: neutral points of transmission control for forward and reverse movement are too far apart, greater than 8°.

Check A009 actuator unit to actuator shaft connection. F08 Step 3: Max. transmission ratio forward point not found. Specified value min. 155°, max. 187° Step 4: Max. transmission ratio reverse point not found. Specified value min. 136°, max. 165°. Check A009 actuator unit to actuator shaft connection. Transmission ratio characteristic not logical, e.g. shifted forward and reverse detected. F05 Step 1: A009 actuator unit does not find neutral point 0 in forwards direction. Step 2: A009 actuator unit does not find neutral point 0 in reverse direction. Check A009 actuator unit to actuator shaft connection. Remedy: 1. Reprogram EOL.

If incorrect values are detected or the conditions are not ERROR message is displayed. = calibration code = fault code F06 See under error message F05 919 .. 0101-1000 925 .. 1001- 934 .. 0101-1000 919 .. 1001- 928 .. 0101-1000 934 .. 1001- 922 .. 0101-1000 928 .. 1001- 922 .. 1001- 931 .. 0101-1000 925 .. 0101-1000 931 .. 1001- See F 11/F 12 Fault code Cause Cause F - Setting and calibrating Fault code Cause F 10 Transmission ratio characteristic not logical, e.g. shifted forward and reverse detected. Repeat calibration. See also error message F 2. Check rotational direction signal from B014 hydrostatic sensor (collecting shaft) F 11/F 12 Step 7: check Step 1 to Step 6 values.

ML transmission ratio not OK. Repeat calibration. See also error message F 2. Then check hydrostatic power branch, e.g. via emergency operation. F 13 1. EOL programmed incorrectly (prior to Step 1) 2. Values stored in A050 basic control unit not logical. Remedy: 1. Reprogram EOL. 2. See 1. Replace A050 basic control unit where necessary. F 14 See F 11/F 12 F 15 1. Maximum forward and/or reverse transmission ratio not achieved. 2. Y005 speed governor solenoid valve (30 km/h ) not OK Remedy: 1. Repeat calibration (see also F2). Then check hydraulic power distribution system if neces- sary, e.g. via emergency operation. 2.

Y005 speed governor solenoid valve Fault code Cause F02 A009 actuator unit reports a fault Frequent cause of fault: During previous fault-generated calibration exit, no "Key reset (ignition OFF/ON)" was carried out F03 A009 actuator unit does not actuate the precise setpoint value. Check that the transmission control runs smoothly, e.g. engage and check emergency opera- tion. F04 Transmission ratio adjustment not effected within 8 sec. Check that the transmission control runs smoothly, e.g. engage and check emergency opera- tion. F05 Step 1: A009 actuator unit does not find neutral point 0 in forwards direction. Step 2: A009 actuator unit does not find neutral point 0 in reverse direction.

Check A009 actuator unit to actuator shaft connection. F06 See under error message F05 F07 Step 2: neutral points of transmission control for forward and reverse movement are too far apart, greater than 8°. Check A009 actuator unit to actuator shaft connection. F08 Step 3: Max. transmission ratio forward point not found. Specified value min. 155°, max. 187° Step 4: Max. transmission ratio reverse point not found. Specified value min. 136°, max. 165°. Check A009 actuator unit to actuator shaft connection.