Fendt 900 Vario COM III — 3 Transmission pressure measurement (fax template)

1005 - Overall system/transmission E - Measuring and testing D ANGER : Perform each high-pressure measurement forwards or backwards for max. 5 seconds, to prevent oil heat-up! 29 T000471 Version 4 31-10-2008 Engine speed Measuring point Engine speed Setpoint value in bar Actual value in bar PH 1600 540±20 * 3 Transmission pressure measurement (fax template) Preparations: travel range II, acceleration stage 4 or transmission in emergency mode (emergency operation from cab using auxiliary lever) 16±2.5 2±0.4 3±0.5 4.2±0.6 5.5±0.8 II. High-pressure measurement Measure the pressure driving forwards and in reverse. 919 .. 0101-1000 925 .. 1001- 934 .. 0101-1000 919 .. 1001- 928 ..

0101-1000 934 .. 1001- 922 .. 0101-1000 928 .. 1001- 922 .. 1001- 931 .. 0101-1000 925 .. 0101-1000 931 .. 1001- 800 1200 1600 2000 800 1200 1600 2000 800 1200 1600 2000 800 1200 1600 2000 800 1200 1600 2000 SM M2 Pressure lubrication E - Measuring and testing Workshop (Address): Workshop (Customer number): Chassis number: Operating hours: Complaint (if available:

specify the fault code) Date, Signature Measuring point Engine speed Setpoint value in bar Actual value in bar PU M5 Pressure, servo pump 800 1200 1600 2000 25±2 26±2 27±2 28±2 P M6 System pressure, transmis- sion 800 1200 1600 2000 25±2 25.5±2 26±2 27±2 ES M4 Inlet pressure 800 1200 1600 2000 16±2 19±2 21±2 24.5±3 AS M3 Outlet pressure 800 1200 1600 2000 9±2 11±2 13±2 16±2.5 SM M2 Pressure lubrication 800 1200 1600 2000 2±0.4 3±0.5 4.2±0.6 5.5±0.8 Measuring point Engine speed Setpoint value in bar Actual value in bar PH 1600 540±20 *