1080 - Transmission/drive train G - Repair I001820 Fig. 61. I001818 Fig. 62. I001718 Fig. 63. I002899 Fig. 64. 27 T000671 Version 2 04-02-2010 Fit the screw plugs on the underside of the transmission housing N OTE : During the filling process, pivot the hydraulic pumps and hydraulic motors by turning the actuator shaft. Monitor the visible hydraulic connections for leaks. 919 .. 0101-1000 925 .. 1001- 934 .. 0101-1000 919 .. 1001- 928 .. 0101-1000 934 .. 1001- 922 .. 0101-1000 928 .. 1001- 922 .. 1001- 931 .. 0101-1000 925 .. 0101-1000 931 .. 1001- Fit the actuator unit and tighten the hex. socket head screws Torque:
25 Nm Unscrew the plug to the PU connection Connect the external oil filler Observe instructions for oil type and quantity Tighten the hydraulic piping G - Repair