Fendt 900 Vario COM III — 1 General description of the common rail system

2000 - Overall system/engine A - General All previous systems operated by generating the fuel injection pressure separately for each injection event. The injection pressure increases in principle with increasing fuel quantity and increasing engine speed. Between injection events, the pressure in the system is low. In contrast to these well-known systems, in the accumulator injection or common rail system, pressure generation is de- coupled from injection events. The generation of pressure bears no relation to either the engine speed or injection quan- tity; the pressure is instead freely selectable within limits and is continuously available from the high-pressure accumulator (rail).

The accumulator comprises the distribution rail and pipes to the injectors. The fuel quantity for the in- dividual cylinders is taken from this accumulator. One injector for each engine cylinder The core of the system is a solenoid-activated injector for every engine cylinder. A pulse from the control unit to the so- lenoid valve in the injector initiates the injection procedure. The discharge cross-section of the injector, the opening du- ration of the solenoid and the accumulated pressure in the common rail system determine the fuel quantity. Variable pressure in the accumulator In the Deutz common rail system, the accumulator pressure is generated by two high-pressure pumps.

These are acti- vated by the camshaft. On 4-cylinder-engines, the camshaft has 2 cams per pump; on 6-cylinder engines it has 3 cams per pump. This means that fuel is delivered into the rail by the pumps, every time an injector is opened. The exact quantity to be injected by the injector is released by the dispensing unit. This keeps the rail pressure constant. In the common rail system, pressure in the accumulator is controlled by means of a pressure sensor. The rail pressure is freely programmable between 700 bar and 1400 bar using a mapping field (programming) and can be adapted to suit the engine's operating conditions.

The control unit, sensors and system functions of the common rail system require more input signals than the standard single pump system. Free selection of the injection pressure in the mapping field The functional separation of pressure generation and injection opens up new possibilities in terms of the combustion pro- cess structure. Injection pressure is freely selectable in the mapping field and remains largely constant during the injec- tion event. The maximum rail pressure is approx. 1400 bar. Further reductions in exhaust gas and noise emissions A reduction in exhaust gas and noise emissions is possible thanks to multiple injection.

Multiple injection means—de- pending on the operating conditions—a pre-injection, main injection and a post-injection. These are triggered by multiple activation of quick-response solenoids. In addition, the injection process can be shaped by controlling the profile of the nozzle needle movement. Hydraulic support on closing the nozzle needle ensures an abrupt end to the injection process. The multitude of possibilities for configuring the injection process opens up new paths towards further reductions in pol- lutant emissions and the fuel consumption of diesel engines.

No major changes to the design of the engine The common rail system can replace conventional injection systems without major changes to the engine. Instead of the injection pumps cylinders 1 and 2, two high-pressure pumps are fitted. The injectors are integrated into the cylinder head like a nozzle-holder combination. 7 T002534 Version 1 04-09-2009 1 General description of the common rail system See the comparison between EMR 2 (COM II) and EMR 3 (COM III). 919 .. 0101-1000 925 .. 1001- 934 .. 0101-1000 919 .. 1001- 928 .. 0101-1000 934 .. 1001- 922 .. 0101-1000 928 .. 1001- 922 .. 1001- 931 .. 0101-1000 925 .. 0101-1000 931 .. 1001- A - General