B077 - Engine fan (speed sen- sor/magnetic clutch) K008 - Relay, starter lockout K063 - Heater flange relay lamp on the instrument panel is energised Y091 - Dispensing unit (fuel) pressure sensor Y006 - Solenoid valve, engine brake exceeds 900 rpm Y094 - Actuator unit, AGR (exhaust gas recirculation) Y095 to Y101 injectors 1 to 6 919 .. 0101-1000 925 .. 1001- 934 .. 0101-1000 919 .. 1001- 928 .. 0101-1000 934 .. 1001- 922 .. 0101-1000 928 .. 1001- 922 .. 1001- 931 .. 0101-1000 925 .. 0101-1000 931 ..
1001- Component Duties 2000 - Overall system/engine A - General Actuators of the EMR 3 (COM III) 10 T002534 Version 1 04-09-2009 A - General Component Duties B077 - Engine fan (speed sen- sor/magnetic clutch) The fan speed is controlled via the engine control unit so that the coolant water temperature is maintained at approx. 95°C. However, the fan can also be con- trolled by the hydraulic oil temperature and the transmission oil temperature. K008 - Relay, starter lockout The starting process is controlled by the engine control unit. When all input sig- nals are present the relay is closed.
If the rotational speed signals (cam- shaft/crankshaft) are not present after 5 sec, the start process is aborted K063 - Heater flange relay The relay is energised at temperatures of 5°C and below.
In addition the indicator lamp on the instrument panel is energised Y006 - Solenoid valve, engine brake The engine brake is actuated by the engine control unit if the engine speed exceeds 900 rpm Y091 - Dispensing unit (fuel) The rail pressure is regulated by the dispensing unit in conjunction with the rail pressure sensor Y094 - Actuator unit, AGR (exhaust gas recirculation) The the actuator unit diverts exhaust gas into the engine Y095 to Y101 injectors 1 to 6 The injectors inject fuel up to 3 times per working cycle