Fendt 900 Vario COM III — 2 B077 electrical viscous fan

2050 - Engine/cooling A - General Instead of a bi-metal viscous coupling, the FENDTD 900 COM III series has an electrical viscous fan installed. The B077 - Engine fan (speed sensor/magnetic clutch) is controlled via the A051 - ECU, engine control unit (EDC 7). and should maintain the coolant temperature at approx. 95°C. The coolant temperature is the main controlled value. I002035 Fig. 17. The electrical viscous fan can also be controlled via the transmission oil temperature. The B009 - Discharge temperature sensor transmits the transmission oil temperature to the A050 - ECU, basic control unit.

The A050 - ECU, basic control unit transmits the temperature via the G-bus to the A051 - ECU, engine control unit (EDC 7). and can thus control the B077 - Engine fan (speed sensor/magnetic clutch). The electr. viscous fan can also be controlled via the hydraulic oil temperature. The B013 - Sensor, hydraulic oil temperature transmits the hydraulic oil temperature to the A007 - Instrument panel. Transmission to the A050 - ECU, basic control unit occurs via K-bus The A050 - ECU, basic control unit transmits the tem- perature via the G-bus to the A051 - ECU, engine control unit (EDC 7). and can thus control the B077 - Engine fan (speed sensor/magnetic clutch). I002034 Fig. 18.