I002039 If the temperature limit is reached, the A051 ECU, engine control unit engages the B077 electr. viscous fan. The B077 electr. viscous fan is not controlled for the transmission oil tempera- ture. Working and steering hydraulics B013 hydraulic oil tempera- ture sensor approx. 85 °C (approx. 240 ohms) If the temperature limit is reached, the A051 ECU, engine control unit engages the B077 electr. viscous fan. The B077 electronic vis- cous fan is not controlled for the hydraulic oil temper- ature. Note 919 .. 0101-1000 925 .. 1001- 934 .. 0101-1000 919 .. 1001- 928 .. 0101-1000 934 .. 1001- 922 .. 0101-1000 928 .. 1001- 922 .. 1001- 931 .. 0101-1000 925 .. 0101-1000 931 ..
1001- 14 T002571 Version 1 04-09-2009 2050 - Engine/cooling A - General Unplug the X1532 separation point and test the speed of the viscous fan with a tachometer Engine speed (rpm) Fan speed (rpm) 1500 rpm Approx. 1710 rpm 1700 rpm Approx. 1938 rpm 1900 rpm Approx. 2166 rpm 2100 rpm Approx. 2394 rpm 2300 rpm Approx. 2622 rpm Designation Sensor Condition for engage- ment Note Transmission B009 discharge tempera- ture sensor In travel range I (field): approx. 93 °C (approx. 54 ohms) If the temperature limit is reached, the A051 ECU, engine control unit engages the B077 electr. viscous fan. The B077 electr. viscous fan is not controlled for the transmission oil tempera- ture.
In travel range II (road): approx. 85 °C (approx. 70 ohms) Working and steering hydraulics B013 hydraulic oil tempera- ture sensor approx. 85 °C (approx. 240 ohms) If the temperature limit is reached, the A051 ECU, engine control unit engages the B077 electr. viscous fan. The B077 electronic vis- cous fan is not controlled for the hydraulic oil temper- ature.