Fendt 900 Vario COM III — 8 Design and function of the high-pressure limiting valve

2060 - Engine/fuel system A - General I002130 Fig. 14. I002131 Fig. 15. The side of the housing that faces the connection to the rail has a bore that is sealed by the conical end of a piston on the sealing seat in the inside of the housing. If the maximum permitted high pressure (approx. 1800 bar) is exceeded, the valve piston (2) opens and the opening pres- sure is then present at the plate washer (6). The larger area causes the pressure in the rail to fall to approx 700 bar. The fuel flows back to the tank via return connection (3). When the fuel passes through the open high-pressure limiting valve, it is rapidly heated.

Therefore the engine can run only a maximum of 4 minutes in emergency mode, after which it is shut down by the A051 - ECU, engine control unit (EDC 7).. The high pressure limiting valve cannot be closed whilst the engine is running; the engine must always be shut down, either by the A051 - ECU, engine control unit (EDC 7). or by the driver. 21 T002572 Version 1 04-09-2009 D ANGER : After switching off the diesel engine, wait at least 30 seconds before starting any work on the fuel system! If the diesel engine is switched off, the pressure-limiting valve closes after approx. 30 seconds. If the A051 - ECU, engine control unit (EDC 7).

detects a fault in the fuel system, it initiates emergency mode. N OTE : 8 Design and function of the high-pressure limiting valve The pressure-limiting valve is a mechanical component. It comprises the following parts. Housing with external thread for screwing onto the rail (high-pressure accumulator) Warning message High-pressure limiting valve opened A fault code FC 1E.1.51 is logged Connection to the return pipe from the rail to the fuel tank (3) 919 .. 0101-1000 925 .. 1001- 934 .. 0101-1000 919 .. 1001- 928 .. 0101-1000 934 .. 1001- 922 .. 0101-1000 928 .. 1001- 922 .. 1001- 931 .. 0101-1000 925 .. 0101-1000 931 ..

1001- 7 Rail (high-pressure accumulator) 3 Low-pressure range (return) Item Designation 2 Valve piston 4 Valve support 5 Pressure spring 6 Plate washer 1 Valve insert Movable piston (2) Pressure spring (5). Duty: A - General Item Designation 1 Valve insert 2 Valve piston 3 Low-pressure range (return) 4 Valve support 5 Pressure spring 6 Plate washer 7 Rail (high-pressure accumulator)