I006261 Fig. 13. The high-pressure accumulator consists of the distribution rail and pipes to the injectors. The fuel is held at high pressure in the high-pressure accumulator. This damps the pressure fluctuations that arise from the pump deliveries and injection events. The pressure remains virtually constant, even when large quantities of fuel are being taken. High-pressure limiting valve The high-pressure limiting valve limits the maximum permitted fuel high pressure in the rail to approx. 1800 bar. This pro- tects the high-pressure circuit from damage. If the engine is running in emergency mode, the high-pressure limiting valve is deliberately opened.
Opening the high- pressure limiting valve rapidly heats the fuel. Therefore the engine can run only a maximum of 4 minutes in emergency mode, after which it is shut down by the A051 - ECU, engine control unit (EDC 7).. B086 - Rail pressure sensor The A051 - ECU, engine control unit (EDC 7). reports the current rail pressure the rail pressure is regulated in conjunction with the dispensing unit. D After switching off the diesel engine, wait at least 30 seconds before starting any work on the fuel system! W : Ensure the utmost cleanliness! See Service Information 14/2007. The rail pressure is displayed as a target and actual value in the Deutz "SERIDA" diagnostics program.
1 High-pressure limiting valve 2 Rail pressure sensor 7 High-pressure accumulator (rail) N OTE : B086 - Rail Drucksensor Aufbau und Funktion des Hochdruck - DBV Hochdruck - DBV und Rail Drucksensor Aus- und Einbau B086 - Rail Drucksensor 2060 - Engine/fuel system A - General 20 T002079 Version 1 20-10-2009 Check Chassis Range! 1 High-pressure limiting valve 2 Rail pressure sensor