0000 - Overall system/tractor B - Faults 71 05-10-2009 selecting EOL and locks programming 922 .. 0101-1000 928 .. 1001- 922 .. 1001- 931 .. 0101-1000 925 .. 0101-1000 931 ..
1001- Fault code DIN brief description Cause Consequences Reference FENDIAS/Note 08.1.43 S028 - Button, rear power lift, right-hand external lower Faulty button, Signal fault Button inoperable until next trouble-free cold start Circuit diagram Hydraulics 08.1.44 A039 - MFA, multifunction armrest Button, stop rear power lift Faulty button, Signal fault Button inoperable until next trouble-free cold start 08.1.45 A039 - MFA, multifunction armrest Transport button, quick lift, rear power lift Faulty button, Signal fault Button inoperable until next trouble-free cold start 08.1.46 A039 - MFA, multifunction armrest Control button, quick lift, rear power lift Faulty button, Signal fault Button inoperable until next trouble-free cold start 08.1.47 A039 - MFA, multifunction armrest Forced lowering button, quick lift, rear power lift Faulty button, Signal fault Button inoperable until next trouble-free cold start 08.1.48 A039 - MFA, multifunction armrest Button, rear power lift Communication fault Button inoperable until next trouble-free cold start 08.1.49 Y055 - Rear pressure compensator lock valve Faulty valve Valve moves to neutral and locks Circuit diagram Hydraulics 08.1.4A Y062 - Solenoid valve, field pressure control (rear) Faulty valve Valve moves to neutral and locks Circuit diagram Hydraulics 08.1.4B A039 - MFA, multifunction armrest Button, auto rear power lift Faulty button (output via TeachIn) No auto mode 08.1.A2 Y077 [HKH] - Cut-off valve, rear EPC EEPROM is faulty (Valve) Valve moves to neutral and locks EOL programming 08.1.A3 Y077 [HKH] - Cut-off valve, rear EPC RAM Test _ Valve moves to neutral and locks Pilot pressure OFF 08.1.A4 Y077 [HKH] - Cut-off valve, rear EPC Flash Test _ Valve moves to neutral and locks Pilot pressure OFF 08.1.A5 Y077 [HKH] - Cut-off valve, rear EPC Incorrect valve code (SA/DA) for selecting EOL Valve moves to neutral and locks EOL programming