Fendt 900 Vario COM III — 14 Fault code 0D.1.00 -

0000 - Overall system/tractor B - Faults 93 05-10-2009 922 .. 0101-1000 928 .. 1001- 922 .. 1001- 931 .. 0101-1000 925 .. 0101-1000 931 ..

1001- Fault code DIN brief description Cause Consequences Reference FENDIAS/Note 0D.1.0F A055 - ECU, data transfer Control bus error on Vario-Doc (transmitter buffer) Possible faulty program- ming, restart tractor 0D.1.10 A055 - ECU, data transfer Control bus error on Vario-Doc (receiver buffer) Faulty parameterisation, restart tractor 0D.1.11 A055 - ECU, data transfer Control bus error on Vario-Doc (transmitter buffer) Faulty parameterisation, restart tractor 0D.1.12 A073 - Terminal (A4) ISO bus mode could not be detected No display on the termi- nal, restart tractor 0D.1.13 A055 - ECU, data transfer Inconsistency in operating data Meaningful system oper- ation not possible, syn- chronisation (call up data) 0D.1.14 A055 - ECU, data transfer Version number for operating data does not correspond with that of the application Meaningful system oper- ation not possible, syn- chronisation (call up data) 0D.1.15 A055 - ECU, data transfer Function not activated in the firm- ware Meaningful system oper- ation not possible, replace hardware 0D.1.17 A055 - ECU, data transfer Time not available or time (RTC) module faulty Meaningful system oper- ation not possible, replace hardware 0D.1.18 A055 - ECU, data transfer Data level at 100% No more entries possi- ble, synchronisation (call up data) 0D.1.19 A055 - ECU, data transfer Data configuration error No more entries possi- ble, synchronisation (call up data) 0D.1.1A A055 - ECU, data transfer Write operation to DataFlash not possible No more entries possi- ble, synchronisation (call up data) 0D.1.22 A055 - ECU, data transfer EEPROM communication report- ing fault upon data receipt System operation not possible, potentially Replace hardware, restart tractor