Fendt 900 Vario COM III — 14 Fault code 0D.1.00 -

0000 - Overall system/tractor B - Faults 95 05-10-2009 922 .. 0101-1000 928 .. 1001- 922 .. 1001- 931 .. 0101-1000 925 .. 0101-1000 931 .. 1001- Fault code DIN brief description Cause Consequences Reference FENDIAS/Note 0D.1.31 A055 - ECU, data transfer Vario-Doc circuit board tempera- ture higher than 60°C Data transfer (via Blue- tooth) not possible, allow tractor (roof area) to cool down 0D.1.33 A055 - ECU, data transfer Break in Vario-Doc internal volt- age; must be between 8 V and 12 V System failure, replace hardware 0D.1.34 ISO bus ISO bus initialisation failed System operation not possible, restart tractor 0D.1.35 A055 - ECU, data transfer ISO application not operational.

Internal fault in ISO bus driver System operation not possible, restart tractor 0D.1.36 A073 - Terminal (A4) Terminal does not answer the request for hardware information System operation not possible, restart tractor 0D.1.37 A073 - Terminal (A4) Terminal does not answer the request for number of buttons System operation not possible, restart tractor 0D.1.38 A073 - Terminal (A4) Terminal does not answer the request for available memory System operation not possible, restart tractor 0D.1.39 A073 - Terminal (A4) Screen deletion operation is not confirmed by the terminal System operation not possible, restart tractor 0D.1.3A A073 - Terminal (A4) Terminal does not confirm the successful loading of screens from the terminal System operation not possible, restart tractor 0D.1.3B A073 - Terminal (A4) Protocol error when uploading object pool or terminal does not confirm successful upload System operation not possible, restart tractor 0D.1.3C A073 - Terminal (A4) Terminal reports fault when sav- ing screens or does not respond to memory request System operation not possible, restart tractor 0D.1.3D A055 - ECU, data transfer A073 - Terminal (A4) ISO bus address request unsuc- cessful, probably no more free addresses in the permitted range System operation not possible, restart tractor