MH MH6.6/MH8.6 — GB COPERTINA.fm

MH6.6 / MH8.6 HYDRAULICS 5-97 Combined radiator with controlled fan drive (No. 7) Lower temperatures result in the load-limit regula- tor supplying a high current to the proportional valve. The control piston is opened wide by the electrical force and creates a by-pass through which the oil flows past the oil motor to the tank, causing the fan to turn at a lower speed. Description The combined radiator comprises three coolers with the foremost cooler in driving direction being traversed by the return oil from the working hydrau- lics, the rearmost one by the coolant from the die- sel engine and the uppermost one by the charge air form the turbocharger.

The fan wheel is driven by a speed-controlled gearwheel motor. The speed is controlled dependent on temperature by the load-limit regulator. At low temperatures, the fan turns slowly. This means that noise emissions are kept low and power demands are minimized. Moreover, the coolant and the hydraulic oil reach their operating temperature very fast. With increasing temperature, the load-limit regula- tor reduces the current to the proportional valve. The control piston opens less so that the oil motor gets a higher amount of oil. The fan speed increases. A pressure-limiting valve integrated in proportional valve (9) protects the fan circuit against pressure peaks.

After engine stop, the oil supply in the oil motor is ensured during the fan wheel delay by a replenishing valve until the fan stops. The flow of cooling air is sucked by the fan wheel from the center of the excavator through the com- bined radiator and discharged to the outside through the air vents in the hood. In the event of defects, e.g. broken cable, the pro- portional valve is without current and the fan wheel turns at maximum speed. In this case, the pres- sure in the fan circuit is limited by the pressure- limiting valve. Gear motor (5) receives pressure oil from gear pump (1) via priority valve (3).

Fan motor (5) is connected to a nitrogen accumula- tor (7) whose function is to absorb sound waves in the hydraulic oil. The pressure oil is also available in (6) of the oil motor where proportional valve Y131 (9) is pro- vided as a by-pass. The load-limit regulator A10 evaluates three tem- perature signals permanently supplied by coolant temperature sensor B13.1, charge-air temperature sensor R10.3 and hydraulic oil temperature sensor R14. The higher of the three values is used for controlling proportional valve Y131. Carefully read personal and machine SAFETY INSTRUCTIONS (at the beginning of this manual)