5-98 HYDRAULICS MH6.6 / MH8.6 Replenishing system for 25/30 km/h version (Nos. 13 and 14) 2 3 1 5 4 8 7 6 Fig. 1 Key 1 Valve housing During forward travel in 2 nd gear, the CU activates solenoid valve Y295 and the fan pressure reaches pressure-reducing valve (3). The adjustable outlet pressure of valve (3) is admitted as replenishing pressure via line (6) to port A1.1 of the control block in which non-return valve (7) is located.
2 Solenoid valve Y295 3 Pressure-reducing valve 4 Fan pressure line 5 Fan pressure branch-off When the travel pressure drops below the replen- ishing pressure during downhill drives, non-return valve (7) opens and the travel oil motor receives additional pressure oil. 6 Replenishing pressure line 7 Non-return valve in port A1.1 8 Leakage-oil line When the travel pressure increases again, non- return valve (7) is closed against the replenishing pressure. Description The replenishing system prevents cavitation in the travel oil motor, especially during downhill drives. During reverse travel and driving in 1 st gear, the replenishing system is off.
Valve housing (1) accomodates solenoid valve Y295 and pressure-reducing valve (3). The replenishing system is supplied with pressure from fan circuit (4) via line (5). Carefully read personal and machine SAFETY INSTRUCTIONS (at the beginning of this manual)