5-114 HYDRAULICS MH6.6 / MH8.6 Pipe break protection valves (Nos. 202 and 210) Description Pipe break protection valves are safety valves that are installed directly at the cylinders. Depending on the function and the use of the cylinder, the pipe break protections are installed at the piston- or rod-side connection of a cylinder. The pipe break protection valve is a hydraulically operated non-return valve with variable flow cross section retaining the load pressure of the oil col- umn in the cylinder without leakage. Inadmissibly high cylinder pressures are reduced via the secondary valve to the control block and from there via the pertaining secondary valve towards the reservoir. Fig.
1 Key A Control block connection The STOP situation in the drawing opposite shows a pipe break protection valve in closed condition. The cylinder pressure acts via port B on the spring cavity behind the non-return valve and at the secondary valve. The valve piston is closed by the pressure assisted by spring force. B Cylinder connection X Pilot-pressure connection The UP situation shows the oil flow from the con- trol block via port A through the valve piston opened by pressure to port B in the cylinder com- partment.
E Compensation line connection, only used with boom cylinders SV Secondary valve, adjustable The DOWN situation shows how the oil column from the cylinder can flow to the contol block after opening of the pipe break protection. Opening is effected by pilot pressure at port X acting on the pilot-control piston. The pilot-control piston is dis- placed against the compensator springs with the plunger opening a pressure-relief valve in the valve piston against the spring. The spring cavity is depressurized towards the control block and the valve piston opens in proportion to the value of the pilot pressure at port X. The STOP position is reached again by shutting off the pilot pressure.
The pilot-control piston ist retracted by the springs. The pressure-relief valve is closed by spring force and the cylinder pressure builds up in the spring cavity behind the valve piston. The valve piston is forced by the load pressure on its seat in the valve, thus retain- ing the oil column in the cylinder without leakage. Fig. 2 Carefully read personal and machine SAFETY INSTRUCTIONS (at the beginning of this manual)