6-4 CALIBRATION MH6.6 / MH8.6 DISPLAY, SERVICE, CALIBRATION General information This menu is used for the calibration of propor- tional and control valves, hydraulic pumps, com- bustion engines and electric and hydraulic motors. Calibration or recalibration is nec- essary for new machines and after repair and replacement of assem- blies. The hydraulic oil temperature must be at least 40 °C. If this is not the case, the calibration procedure will be aborted (see also the chapter: "After engine start / warm-up" in the operating instructions). Fig.
1 - START CALIBRATION starting the calibration - DEFAULT preset values The individual calibration categories can be se- lected with the arrow UP [ ] or with the arrow DOWN [ ] key. After confirming the selection "START CALI- BRATION" with the SET key, the calibration pro- cedure is performed. The calibration procedure can be aborted at any time by pressing the arrow UP [ ] key. After the abortion, the message "CALIBRATION ABORTED" is displayed with the program returning after 3 seconds to the next higher menu. After confirming the selection with the SET key you are asked whether you want to perform the calibration confirmed "START CALIBRATION" or "DEFAULT" (Fig. 1).
Carefully read personal and machine SAFETY INSTRUCTIONS (at the beginning of this manual)