MH6.6 / MH8.6 REPAIR INSTRUCTIONS 8-13 Securing the machine Risk of injury Do not shut off the engine from full load, but rather let it continue to run at idling for about 3 minutes for cool- ing down. The machine must not be started by unauthorized persons. The machine must therefore be se- cured. Shut off the automatic speed reduc- tion function before shutting off the engine as there will otherwise be no 'WARMUP' phase during the next start-up and the engine will run im- mediately at full speed. Secure the machine as described below: - before performing any modification or fitting work on the working equipment; - before performing any servicing or repair work on the machine.
Shut off the engine. - Park the machine on level and firm ground. - Turn the electrical system key-switch to position I (ignition ON). - Lock the superstructure. - Depressurize the hydraulic system. - Stand the working equipment on the ground. - Withdraw the key from the electrical system key- switch. - Apply the parking brake. - Shut off the pilot control. - Turn off the battery main switch and withdraw the lever. - Before working on the electrical system or before performing welding work on the machine, dis- connect the batteries. - Insulate the connecting terminals. Carefully read personal and machine SAFETY INSTRUCTIONS (at the beginning of this manual)