Cummins — 4021389

B3.9, B4.5, B5.9 Industrial Cooling Fan Belt Tensioner Section 6 - Maintenance Procedures at 1000 Hours or 1 Year Page 6-1 Maintenance Procedures - Overview General Information All maintenance checks and inspections listed in previous maintenance intervals must also be performed at this time, in addition to those listed under this maintenance interval. Cooling Fan Belt Tensioner Maintenance Check With the engine turned off, check that neither the top nor bottom tensioner arm stop is touching the cast boss on the tensioner body. If either of the stops is touching a boss, the alternator belt must be replaced.

Check to make certain the correct belt part number is being used if either condition exists. When using a steam cleaner, wear safety glasses or a face shield, as well as protective clothing. Hot steam can cause serious personal injury. WARNING WARNING Wear safety glasses or a face shield, as well as protective clothing, to prevent personal injury when using a steam cleaner or high-pressure water. Check the tensioner pulley and body for cracks. If any cracks are noticed, the tensioner must be replaced. Refer to a Cummins® Authorized Repair Facility. Check the tensioner for dirt buildup. If this condition exists, the tensioner must be removed and steam- cleaned.

With the cooling fan belt removed, check that the bottom tensioner arm stop is in contact with the bottom tensioner arm stop boss on the tensioner body. If these two are not touching, the tensioner must be replaced.