Cummins — 4021389

Fan Hub, Belt Driven B3.9, B4.5, B5.9 Industrial Page 6-2 Section 6 - Maintenance Procedures at 1000 Hours or 1 Year Inspect the tensioner for evidence of the pivoting tensioner arm contacting the stationary circular base. If there is evidence of these two areas touching, the pivot tube bushing has failed and the tensioner must be replaced. The worn tensioner that has play in it or a belt that “walks” off its pulley possibly indicates pulley misalignment. NOTE: Maximum pulley misalignment is 3 degrees. This measurement can be taken with a straightedge and an inclinometer. Install the belt. Fan Hub, Belt Driven Maintenance Check Remove the drive belt. NOTE:

The fan hub must rotate without any wobble or excessive end play. Fan Hub End Play mm in 0.15 MAX 0.006