Cummins — 4021389

Cooling System B3.9, B4.5, B5.9 Industrial Page 7-4 Section 7 - Maintenance Procedures at 2000 Hours or 2 Years The system must be filled properly to prevent air locks. During filling, air must be vented from the engine coolant passages. Wait 2 to 3 minutes to allow air to be vented then add mixture to bring the level to the top. CAUTION For rear gear train engines, a dearation port next to the water outlet connection vents air to the top tank of the cooling system. This provides adequate venting for a fill rate of 19 liters per minute [5 U.S. gallons per minute]. NOTE: An alternative to using sodium carbonate, as outlined in this procedure, is to use RESTORE™.

RESTORE™ is a heavy-duty cooling system cleaner that removes corrosion products, silica gel, and other deposits. The performance of RESTORE™ is dependant on time, temperature, and concentration levels. An extremely scaled or flow-restricted system, for example, can require higher concentrations of cleaners, higher temperatures, or longer cleaning times or the use RESTORE Plus™. Up to twice the recommended concentration levels of RESTORE™ can be used safely. RESTORE Plus™ must be used only at its recommended concentration level. Extremely scaled or fouled systems can require more than one cleaning. CAUTION Do not install the radiator cap.

The engine is to be operated without the cap for this process. Fill the system with a mixture of sodium carbonate and water (or a commercially available equivalent). NOTE: Adequate venting is provided for a fill rate of 19 liters per minute [5 U.S. gallons per minute]. WARNING Coolant is toxic. Keep away from children and pets. If not reused, dispose of in accordance with local environmental regulations. Operate the engine for 5 minutes with the coolant temperature above 80°C [176°F]. Shut the engine off, and drain the cooling system.