B3.9, B4.5, B5.9 Industrial Troubleshooting Symptoms Charts Section TS - Troubleshooting Symptoms Page TS-31 Engine Runs Rough or Misfires Cause Correction Allow the engine to warm to operating temperature. If the engine will not reach operating temperature, refer to the Coolant Temperature Below Normal symptom tree. STEP 1 Engine is cold ............. OK Go To Next Step Check for air in the fuel system. Tighten or replace the fuel connections, fuel lines, fuel tank standpipe and fuel filters as necessary. Vent air from the system. Refer to a Cummins® Authorized Repair Location. STEP 2 Air in the fuel system .............
OK Go To Next Step STEP 3 Fuel grade is not correct for the application or the Operate the engine from a tank of high-quality fuel. Refer to Procedure 018-002 (Fuel Recommendations and Specifications) in Section V. ............. fuel quality is poor OK Go To Next Step STEP 4 Fuel leak ............. Check the fuel lines, fuel connections, and fuel filters for leaks. Refer to the OEM service manual. OK Go To Next Step STEP 5 Fuel filter is plugged ............. Measure the fuel pressure before and after the fuel filter. Refer to a Cummins® Authorized Repair Location. OK Go To Next Step Check the flow through the filter to locate the source of the restriction.
Refer to a Cummins® Authorized Repair Location. STEP 6 Fuel supply is not adequate ............. OK Go To Next Step Check the fuel lift pump for correct operation. Check the pump output pressure. Replace the fuel lift pump if necessary. Refer to a Cummins® Authorized Repair Location. STEP 7 Fuel lift pump is malfunctioning ............. OK Go To Next Step STEP 8 Engine mounts are worn, damaged, or not correct ............. Check the engine mounts. Refer to the OEM service manual. OK Go To Next Step STEP 9 Contact a Cummins® Authorized Repair Facility