Fuel Filter (Spin-On Type) B3.9, B4.5, B5.9 Industrial Page 5-6 Section 5 - Maintenance Procedures at 500 Hours or 6 Months Batteries can emit explosive gases. To reduce the possibility of personal injury, always ventilate the compartment before servicing the batteries. To reduce the possibility of arcing, remove the negative (-) battery cable first and attach the negative (-) battery cable last. WARNING Connect the batteries. Prime General Information Controlled venting is provided at the injection pump through the fuel drain manifold.
Small amounts of air introduced by changing the filters or injection pump supply line will be vented automatically if the fuel filter is changed in accordance with the instructions. However, manual bleeding will be required if one of the following conditions exists: The fuel filter is not filled prior to installation The fuel injection pump is replaced The high-pressure fuel line connections are loosened, or the lines are replaced It is an initial engine start-up or start-up after an extended period of no engine operation. Refer to Procedure 006-015 (Fuel Filter (Spin-On)) in Section 6 for proper venting of the low pressure side of the fuel system.
Refer to the Procedure 005-012 (Fuel Injection Pumps, In- Line) in Section 5 to determine if venting the fuel pump is necessary. Or, refer to Procedure 005-014 (Fuel Injection Pumps, Rotary) in Section 5 to determine if venting the fuel pump is necessary. Refer to Procedure 006-051 Injector Supply Lines (High Pressure) in Section 6 for venting of the high pressure side of the fuel system.