Doosan P086TI — Doosan P086TI User Manual

® Tighten the coupling fixing bolts and nuts to specified torque. Torque ‘| 6.0 ~ 6.5 kg.m 6.3. Cylinder Compression 1) Stop the engine Pressure after warming it up, then remove the nozzle assemblies. EA905003 2) Install a nozzle special holder too! (gauge hole and adapter) connect in the com- pression pressure gauge to the adapter. 3) Cut then off fuel circulation, measure rotate compression the starter, pressure of each cylinder. EA905004 Standard value 25 ~ 28 kg/cm? Limit Difference between 24 kg/cm? or less each cylinders Within + 10% % Testing conditions : at water temperature of 20°C and speed of 200 rpm (10 turns) -49-