6.4. V-belts The tension of the V-belts should be checked after every 2,000 hours of operation. 1) Change the V-belts if necessary lf in the case of a multiple belt drive, wear or differing tensions are found, always replace the complete set of belts. 2) Checking condition Check V-belts for cracks, oil, overheating and wear. 3) Testing by hand The tension is correct if the V-belts can be pressed in by about the thickness of the (no V-belt. more midway Press here 10~15mm between the belt pulleys) A more sion precise check is possible only of the V-belt ten- Water pump by using pulley a V-belt Alternator tension tester.
pulley Crank pulley 4) Measuring @ V-belt’ —_ Eago2c06 tension Lower indicator arm (1) into the scale. ® Apply tester to belt at a point midway between two pulleys so that edge of contact surface (2) is flush with the Vbelt. @ Slowly depress pad (3) until the spring can be heard to disengage. This will cause the indicator to move after the upwards. lf EA606011 pressure spring has is maintained disengaged a false reading will be obtained! ® Reading of tension @ Read * of the tensioning force of the QO belt at the point where the top surface of the indicator arm (1) intersects with the scale. ®@ Before that the taking readings indicator arm make ensure remains in eh its position. EA606012 -50-