Operation—Operating the Machine Operating Auxiliary Hydraulics Manual Controls For manual controls, use right control lever (2) to operate auxiliary hydraulic functions. Connect attachment to standard male and female couplers (7 and 8). Roll auxiliary proportional switch (4) forward or backward to vary hydraulic flow rate and direction depending on desired attachment function. Releasing the auxiliary proportional switch stops all auxiliary hydraulic flow. 1 4 TX1066657 —UN—22OCT09 2 3 To set continuous auxiliary flow, press and release auxiliary flow set switch (3) while the proportional switch is actuated in the desired direction.
This will set the auxiliary hydraulics to run at full flow in the direction selected. Continuous auxiliary hydraulic flow will continue without pressing the auxiliary proportional switch. If continuous flow is active and the auxiliary proportional switch is moved in either direction or the flow set switch is pressed, continuous flow will be cancelled and proportional auxiliary hydraulic flow will resume. Manual Controls TX1067192A —UN—03NOV09 If operator needs to exit the machine with hydraulics enabled, press upper half of auxiliary hydraulic override switch (5) momentarily to activate bypass mode.
The message, Auxiliary Override, will appear on engagement and monitor unit (EMU) display and alarm will sound. IMPORTANT: Avoid attachment damage. Only use high flow switch (6) with high flow attachments. Auxiliary Override and High Flow Switches If attachment requires a high hydraulic flow rate to operate, connect attachment to high flow male and female couplers (9 and 10), if equipped. Press upper half of high flow switch (6) momentarily to activate high flow option. Amber hydraulic high flow icon will appear on EMU. TX1067104A —UN—03NOV09 IMPORTANT:
Prevent damage to the attachment motor, always connect attachment case drain coupler (11) first when installing attachment and disconnect last when removing attachment. NOTE: Attachment case drain coupler is only used when required by attachment. High Flow Shown 1— Left Control Lever 2— Right Control Lever 3— Auxiliary Flow Set Switch 4— Auxiliary Proportional Switch 5— Auxiliary Hydraulic Override Switch 6— High Flow Switch (if equipped) 7— Standard Male Coupler 8— Standard Female Coupler 9— High Flow Male Coupler (if equipped) 10— High Flow Female Coupler (if equipped) Attachment Case Drain Coupler (if equipped) Continued on next page OUT4001,0000530 -19-31JAN13-1/3 2-2-18 071713 PN=70