. OPERATION TROUBLESHOOTING code the display panel B take remedies based upon the Note: If a problem display appears on display panel B, check the fault code. For details, see "METHOD OF USING FAULT CODE DISPLAY MODE (PAGE 3-30)". When contacting your Komatsu distributor, please give the fault code also. 3 - 149 MONITOR PAN Whe n an error (multi-information table on appropriate (1): Display p anel B (2): Warning lamp (red REMARK If occur ime, their failure code s are arr ang ed in the order of seriousness in the display.
The order of seriousness in this case E0 E01, starting from the most serious one E02 and Error code Abnormality Method of displaying abnormality Remedy E01 Backup alarm does not sound Fan rotation is too fast Displays in turn with service meter Automatic functions stop, some functions stop, but operation is possible. Please contact your Komatsu distributor for repairs. E02 Tilt limit does not work Does not shift up or shift down Pitch does not work Abnormality code and service hour are displayed in turn on service meter portion, caution lamp flashes, buzzer sounds If user stops engine and then starts again, operations are possible without limit functions. However, user must be careful.
Please contact your Komatsu distributor immediately for repairs. E03+CALL Number of speed ranges that can be used is limited Engine does not run at full speed Excessive shock when shifting gear Turning ability becomes poor Excessive braking shock Abnormality in engine water temperature sensor Abnormality code and service hour are displayed in turn on service meter portion, caution lamp flashes, buzzer sounds Move machine to a safe place, then contact your Komatsu distributor immediately for repairs.
E04+CALL Engine control impossible Travel impossible Machine does not stop Abnormality code and service hour are displayed in turn on service meter portion, caution lamp flashes, buzzer sounds Stop machine, then contact your Komatsu distributor immediately for repairs.