. OPERATION TROUBLESHOOTING 3 - 150 CHASSIS ( ) : Always contact your Komatsu distributor when dealing with these items. In cases of problems or causes which are not listed below, contact your Komatsu distributor for repairs. Problem Main causes Remedy Oil pressure in torque converter fails to rise Check, repair ( Check, replace) Add oil to the specified level. For details, see CHECK BEFORE STARTING Clean.
For details, see EVERY 500 HOURS SERVICE Torque converter is overheats Clean radiator core See ENGINE related parts ( Clean or repalce) Go to "Oil pressure in torque converter fails to rise" ( Replace gear pump) Torque converter oil temperature gauge dose not work ( Replace oil temperature gauge) ( Check, repair) Lacks drawber pull (machine dose not pick up speed) See ENGINE related parts Go to " Oil pressure in torque converter fails to rise" Machine will not move off when joystick is placed at FORWARD Add oil to specified level.
For details, see CHECK BEFORE STARTING Go to oil pressure in torque converter fails to rise ( Check, repair) Set to FREE position Dose not steer even when steering is operated Brake is not applied on side which is pulled Parking brake lever is at LOCK position Defective lever wiring Abnormality HSS pump Abnormality HSS motor ( Adjust linkage. Check brake pressure) Set to FREE position ( Check, repair) ( Check, replace) ( Check, replace) Machine doesn't stop when brake pedal are depressed ( Adjust linkage) ( Check brake pressure) Track comes off Adjust track tension. For details, see WHEN REQUIRED Sprocket develops abnormal wear Adjust track tension.
For details, see WHEN REQUIRED Machine does not travel in straight line Defective adjustment of HSS controller Abnormality HSS pump ( Adjust) ( Replace)