Caterpillar C7 ACERT, C9 ACERT, C11 ACERT, C13 ACERT, C15 ACERT, C18 ACERT, C27 ACERT, C32 ACERT — Caterpillar C7 ACERT, C9 ACERT, C11 ACERT, C13 ACERT, C15 ACERT, C18 ACERT, C27 ACERT, C32 ACERT User Manual

Starting and Stopping the Engine (1) Refer to the appropriate Parts Manual for your engine. (2) If a third party relay is used, select a relay that will operate between 1.0A and 2.0A. (3) Fabricated to length 9.3 J1939 Engine Shutdown 9.3.1 J1939 Engine Shutdown Operation Industrial engine software released November 2007 and later (see the software availability chart that follows) provides the J1939 Engine Shutdown feature with the purpose of allowing another controller to command the engine control, via the J1939 data link, to disable fuel injection and shut down the engine.

The device requesting the shutdown must broadcast the request over the data link at a one-second interval until the engine has stopped completely. Fuel injection will be enabled if the requesting device changes the broadcast message from “Shutdown” to “Run” or if the engine control does not receive and shutdown request within three seconds of the last broadcasted request. An ECU reset also enables fuel injection since the engine control software will initialize to the “Run” status. Refer to Section 18.1.2.2 for more detail on the J1939 Parameter Group Number (PGN) used for the broadcast of the engine shutdown request.

A P P L I C A T I O N A N D I N S T A L L A T I O N G U I D E 51 REQUIRED PARTS Part Number Description Qty (1) Air Shutoff System 1 (2) Relay 1 N/A Circuit Protection 1 9X-3402 Connector Socket 2 N/A Terminal (Relay)(2) 4 (1) Terminal (Solenoid) 1 N/A 10 AWG Wire (+ Battery) (3) N/A 18 AWG Wire (ECU) (3)