Engine Speed Demand 11.13 Engine Acceleration Rate 11.13.1 Engine Accel. Rate Operation Engine Accel. Rate is a programmable parameter. It allows the customer to program the acceleration and deceleration rate during PTO and intermediate speed operations. See PTO Ramp Up/Ramp Down, PTO Set/Resume, and Intermediate Engine Speed for further information. NOTE: Engine accel. rate has no effect on engine acceleration when using a PWM throttle position sensor . 11.13.2 Engine Accel. Rate Configuration Refer to PTO Modes and Intermediate Engine Speed configuration. 11.13.3 Engine Acceleration Rate Installation No installation is necessary.
11.14 Throttle Arbitration Strategy 11.14.1 Throttle Arbitration Strategy Operation If more than one speed input device or method is used, then the engine ECU chooses or “arbitrates” between the different input devices. Strategy summary: • Different priority signals are present: The engine ECU compares multiple speed input signals and identifies the signal with the highest priority. The highest priority speed input signal is always the signal on which the engine ECU acts. • Same priority signals are present: If two input signals have the same priority (e.g., PTO and TPS), then the ECU selects the preferred signal based on the arbitration strategy.
“Max wins” means the greater (higher rpm) speed input signal is the signal selected by the ECU. For example: If an engine receives two speed input signals, one from a PTO and one from a TPS, and if the TPS commands a speed above the set PTO speed, the engine responds to the TPS signal. A P P L I C A T I O N A N D I N S T A L L A T I O N G U I D E 77